    Single-channel potentiostat

    <
    >
    Portable potentiostat/galvanostat/EIS CS100ME

    CS100ME supports full electrochemical methods. It has built-in chargeable li-ion battery and Bluetooth communication, ideal for field test, sensor application.

    Size / weight:15 x 9 x 3 (cm), 500g

    Communication: USB / Bluetooth

    Power: USB / built-in 10AH@3.7V Li-ion battery 

    Support 2-, 3-or 4-electrode system

    Maximum current: ± 100mA

    Potential control range: ±10V

    EIS frequency range: 10μHz~1MHz

    Compliance voltage: ±10V

    Share:
    View:1725
    Related Application
    Contact Us
    Corrtest Instruments
    Jinfeng Building A, Intl Enterprise Center, Optics valley Ave.,East lake High-tech Dev. Zone, Wuhan city, 430074, China
    Email: sales2@corrtest.com.cn
    Phone/WhatsApp: +86 13469965984
    Product Introduction
        CS100ME handheld potentiostat supports full electrochemical methods, including potentiostatic/galvanostatic polarization curve, Cyclic voltammetry analysis, impedance(EIS), and galvanic current measurement. etc. It has built-in chargeable li-ion battery and Bluetooth communication. The device supports laptop/computer software or APP.  It can be used for electrochemical tests in field or special non-electricity environment. CS100ME can be a convenient handheld tool for researchers of energy& materials, environment protection, biosensor, foods &drugs, corrosion protection etc. Maximum current is ±100mA

        The voltage control range is ±10V, compliance voltage is ±10V, the maximum current output is ±100mA, and the minimum current resolution can reach 1pA. The EIS frequency range is 10μHz~1MHz.

    1000 CS100

    Features

    - Small & light, handheld and convenient

    - Easy to install and use

    - High accuracy, current resolution can reach to 1pA, and measurement accuracy is 0.1% of the range.

    -during outdoor test, a laptop’s USB port can be used for both charging and communicating

    - The circuit adopts floating design. Electrochemical parameters of the grounded system can be measured without an isolation transformer.

    600拷贝-3

    Thanks to its small size with comprehensive electrochemical functions, it’s typically used for:

    - Battery materials’ performance test in a glove box

    - Ultra-low detection limit of heavy metal ions for water quality test in environmental protection field

    - Low current detection in biosensor thanks to high current accuracy  

    - Effective ingredients detection in food and drug industry  

    - Outdoor bridge corrosion and soil corrosion measurements


    Note: maximum current during experiment doesn’t exceed ±100mA then the handheld potentiostat can be used. If exceeds ±100mA an ordinary size potentiostat with maximum current ±2A should be considered.


    Specifications

    Specifications

    Size / weight:15 x 9 x 3 (cm), 500g

    Communication: USB / Bluetooth

    Power supply: USB / built-in Li-ion battery 10AH@3.7V 

    Support 2-, 3-or 4-electrode system

    Maximum current: ± 100mA

    Potential control range: ±10V

    EIS frequency range: 10μHz ~ 1MHz

    Compliance voltage: ±10V

    Current range: 200pA~200mA, 10 ranges

    Potential range:±200mV ±2V, ±5V, ±10V

    Potential accuracy: 0.1%× full range

    Minimum potential resolution: 1mV

    Current accuracy: 0.1%× full range

    Minimum current resolution: 1pA

    Reference electrode input impedance: 1013Ω||8pF

    AC amplitude: 0~±2.5V

    Signal response bandwidth: 1MHz

    Max. acquisition rate: 150,000 data points/s

    CV and LSV scan rate: 0.001mV~ 10V/s

    Techniques

    Electrochemical techniques - CS100ME

    Stable polarization

    · Open Circuit Potential (OCP)

    · Potentiostatic (I-T curve)

    · Galvanostatic

    · Potentiodynamic (Tafel plot)

    · Galvanodynamic (DGP)

    Transient Polarization

    · Multi Potential Steps

    · Multi Current Steps

    · Potential Stair-Step (VSTEP)

    · Galvanic Stair-Step (ISTEP)

    Chrono Method

    · Chronopotentiometry (CP)

    · Chronoamperometry (CA)

    · Chronocaulometry (CC)

    Voltammetry

    ·Linear Sweep Voltammetry (LSV)

    · Cylic Voltammetry (CV)

    · Staircase Voltammetry (SCV) #

    · Square Wave Voltammetry (SWV) #

    · Differential Pulse Voltammetry (DPV) #

    · Normal Pulse Voltammetry (NPV)#

    · Differential Normal Pulse Voltammetry (DNPV) #

    · AC Voltammetry (ACV)

    · 2nd harmonic AC Voltammetry (SHACV)

    · Fourier Transform AC Voltammetry (FTACV)

    # there is correspinding Stripping Voltammetry

    Electrochemical Impedance Spectroscopy (EIS)

    · Potentiostatic EIS (Nyquist, Bode)

    · Galvanostatic EIS

    · Potentiostatic EIS (Optional freq.)

    · Galvanostatic EIS(Optional freq.)

    · Mott-Schottky

    · Potentiostatic EIS vs. Time (Single freq.)

    · Galvanostatic EIS vs. Time (Single freq.)

    Corrosion Measurements

    · Potentiodynamic (Tafel plot)

    · Cyclic polarization curve (CPP)

    · Linear polarization curve (LPR)

    · Electrochemical Potentiokinetic Reactivation (EPR)

    · Electrochemical Noise (ECN)

    · Zero resistance Ammeter (ZRA)

    Battery test

    · Battery Charge and Discharge

    · Galvanostatic Charge and Discharge (GCD)

    · Potentiostatic Charging and Discharging(PCD)

    · Potentiostatic Intermittent Titration Technique(PITT)

    · Galvanostatic Intermittent Titration Technique(GITT)